203210 Cross Reference Part Number Inquiry | SINFT Filter Customization

Replace DC VG-2 Desiccant Breather

Desiccant Breathers Protect Diesel Fuel Storage Reservoirs, Gearboxes, Pumps And Other Industrial Equipment From Moisture And Particulateok7Stainless steel filter element & Hebei Sinft Filter

DC VG-2 Desiccant Breather

Check Valve Design — Extended Service Life

Cross Replace DC-VG-2 features a built-in check valve that provides a system pressure increase without generating excessive strain, and only operates when necessary. This mechanism prevents premature saturation of silica gel and significantly prolongs product service life.ok7Stainless steel filter element & Hebei Sinft Filter

When contaminated air enters the top of the breather, it passes through layered filter media, preventing solid particles from entering the system and causing undue wear to equipment surfaces.ok7Stainless steel filter element & Hebei Sinft Filter

DC VG Series Product View DC VG Series Application

Cross Replace VG Desiccant Breather Parameter

Part Number (SINFT) Unit Height
(in / mm)
Unit Diameter
(in / mm)
Connection Size Silica Gel
(lbs / g)
Adsorption Capacity
(fl oz / ml)
Max. Flow Rate
(cfm)
Max. Flow Rate
(lpm)
Filter Efficiency Temp. (°F) Temp. (°C) Replace DC-VG
SFT-VG-BB 3.87 / 98 2.52 / 64 3/8" Multi-Fit (NPT, BSPP, BSPT) 0.1 / 59 0.8 / 23 1 @ 1 psid 41 3μ absolute (β₃≥200) -20° to 200° -29° to 93° DC VG-BB
SFT-VG-1 5.36 / 136 2.52 / 64 3/8" Multi-Fit (NPT, BSPP, BSPT) 0.3 / 127 1.7 / 50 1 @ 1 psid 41 3μ absolute (β₃≥200) -20° to 200° -29° to 93° DC VG-1
SFT-VG-2 6.00 / 152 4.10 / 104 1" Multi-Fit (NPT, BSPT, NPSM) 0.8 / 365 5 / 142 12 @ 1 psid 340 3μ absolute (β₃≥200) -20° to 200° -29° to 93° DC VG-2
SFT-VG-3 8.00 / 203 4.10 / 104 1" Multi-Fit (NPT, BSPT, NPSM) 1.4 / 643 9 / 251 11 @ 1 psid 311 3μ absolute (β₃≥200) -20° to 200° -29° to 93° DC VG-3
SFT-VG-4 10.00 / 254 4.10 / 104 1" Multi-Fit (NPT, BSPT, NPSM) 2.0 / 913 12 / 356 10 @ 1 psid 283 3μ absolute (β₃≥200) -20° to 200° -29° to 93° DC VG-4
SINFT VentGuard Series

SFT-VG-4 Vent Guard Detailok7Stainless steel filter element & Hebei Sinft Filter

SINFT VentGuard Seriesok7Stainless steel filter element & Hebei Sinft Filter

Gearboxes, reservoirs and pumps all "breathe" in use. As air contracts or expands or as entering fluid displaces air in a system, outside air is drawn in from the atmosphere. Unfortunately, this breathed-in air carries water and particulate that will accumulate to contaminate your system.ok7Stainless steel filter element & Hebei Sinft Filter

A desiccant breather is a straightforward solution to the problem, blocking moisture and particles from entering. Testing of leading competitors has shown that Sinft-Dri Desiccant Breathers average almost 20% greater moisture-retention capacity versus leading brands.ok7Stainless steel filter element & Hebei Sinft Filter

Our unique design features a longer body, which permits 10% greater volume of silica gel desiccant beads when compared to leading competitors, providing extended moisture-retention capacity and longer service intervals.ok7Stainless steel filter element & Hebei Sinft Filter

Advanced Silica Gel

Desiccant removes water from air prior to it entering your system, tank or equipment. Our longer body design allows 10% greater silica gel volume versus leading competitors, providing nearly 20% greater moisture-retention capacity.ok7Stainless steel filter element & Hebei Sinft Filter

Built-In Status Indication

Desiccant gel changes color from blue to pink to indicate that it is removing moisture, as well as when to replace the breather.ok7Stainless steel filter element & Hebei Sinft Filter

Step Up To Superior Protection

When contaminated air enters the top of the breather, it passes through layered filter media, preventing solid particles from entering the breather and causing undue wear to your equipment surfaces. Filtered air passes through a bed of Sinft-Dri™ silica gel, which removes harmful moisture from the air. The silica beads also work to attract moisture from inside the equipment reservoir during service or shut-down, keeping the equipment dry.ok7Stainless steel filter element & Hebei Sinft Filter

The addition of check-valves in our CV breather is ideal for low-flow and intermittent operations in high humidity conditions. Standard breathers provide simple, yet dependable protection from moisture and particulate contamination in lubricants and equipment across multiple industries and applications. These versatile breathers are five times more effective than the leading non-desiccant breathers, providing optimal defense against humidity for your applications.ok7Stainless steel filter element & Hebei Sinft Filter

Application

For example, a gearbox for wind power generation:ok7Stainless steel filter element & Hebei Sinft Filter

Gearboxes in wind turbines differ from those in high-speed machinery. In industrial gearboxes, the progress of failure can occur in weeks, days, or even hours. In wind turbines, the impact of contaminants on slower turning gear drives is slow and insidious. Nevertheless, the mean time between failure (MTBF) for gears and shaft-support bearings can be increased by as much as two to three times by maintaining optimum levels of fluid cleanliness and dryness.ok7Stainless steel filter element & Hebei Sinft Filter

SINFT® designs, manufactures and markets a complete line of Filter and Strainer Replacement Elements which are functionally and dimensionally interchangeable with industrial OEM filter manufacturer elements.